用 DumbMonit 监控 Server hardware (Redfish)
Fans, temperatures, power supplies, drives and memory, read from the BMC (iDRAC, iLO…).
产品说明为英文,与产品内一致。页面标签使用您的语言。
DumbMonit 监控的内容
A server's own hardware, read from its management controller (BMC): fans, temperatures against their own thresholds, power supplies and their redundancy, drives, memory, processors and the event log. Redfish is the HTTPS interface the DMTF standardised for management controllers, and every current one speaks it: Supermicro, Dell iDRAC, HPE iLO, Lenovo XClarity Controller, ASRock Rack, OpenBMC. It is the right way to watch server hardware. A BMC's SNMP agent, by contrast, usually describes the BMC itself — its small ARM Linux, its memory, its network links — and not the server it manages (see SNMP).
典型用途. Server fans, temperatures, power supplies and drives, read from its BMC
示例
- Supermicro BMC
- Dell iDRAC
- HPE iLO
- Lenovo XClarity Controller
- ASRock Rack BMC
连接方式
您需要准备
- Management controller account
需要开放的网络端口
443/TCPRedfish API (HTTPS, default)
设置步骤: Create a read-only account on the management controller
Open the web interface of the management controller (BMC), not the operating system of the server.
Create a local user named as follows, with a long password used nowhere else.
dumbmonitGive it the read-only right of your vendor, listed below.
In DumbMonit, enter the controller address (bmc.lan or 10.0.0.50) with that user name and password.
注意. Do not reuse the controller's factory account, which can power the server off and reflash the firmware; a self-signed certificate needs "Accept an unverifiable certificate" ticked.